I-Environmental-friendly Gas insulated Ring Main Unit GHXH-12

Incazelo emfushane:


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Isingeniso esijwayelekile

I-GHXH-12 yokuvikela imvelo igesi egqunywe indandatho yochungechunge lweyunithi eyinhloko iyisethi ephelele yamadivayisi okusabalalisa amandla we-12kV, i-AC 50Hz yezigaba ezintathu, ibha yebhasi eyodwa kanye nesistimu ehlukaniswe ibhasbha eyodwa. Umkhiqizo unezici zesakhiwo esilula, ukusebenza okuguquguqukayo, ukuxhuma okuthembekile, ukufakwa okulula, njll. Unganikeza izixazululo ezanelisayo zezobuchwepheshe ngezikhathi ezihlukahlukene zohlelo lokusebenza kanye nabasebenzisi abahlukene. Ukwamukelwa kobuchwepheshe bezinzwa kanye nobuchwepheshe bolwazi, kuhlanganiswe nokusebenza kobuchwepheshe kanye nezikimu zokumisa ezilula nezivumelana nezimo, kungahlangabezana nezidingo ezihlala zishintsha zemakethe futhi zifanele izidingo zobuhlakani begridi.

I-GHXH-12 yokuvikela imvelo igesi insulated main unit series ilungele inethiwekhi yezimboni kanye ne-civil cable ring kanye namaphrojekthi wenethiwekhi yokusabalalisa. Njengokwamukelwa nokusatshalaliswa kwamandla kagesi, kufanelekile ikakhulukazi ukusatshalaliswa kwamandla ezindaweni zokuhlala zasemadolobheni, iziteshi ezincane zesibili, iziteshi zokuvula nokuvala, amabhokisi egatsha lezintambo, iziteshi ezincane zohlobo lwamabhokisi, amabhizinisi ezimboni kanye nezimayini, izitolo ezinkulu, izikhumulo zezindiza, imigwaqo ehamba ngaphansi. , ukukhiqizwa kwamandla omoya, izinkundla , izitimela, imigudu nezinye izindawo ezisetshenziswayo.

I-GHXH-12 yokuvikela imvelo uchungechunge lweyunithi enkulu yeringi egqunywe ngegesi ihlangabezana namazinga afanele kazwelonke, amazinga emboni yamandla namanye amazinga. Ukushintsha kwayo kanye nezingxenye zikagesi eziyinhloko amamojula ahlanganisiwe, izingxenye eziqhutshwayo phakathi kwezigaba zingamaphakheji aqinile okufakwa ngaphakathi, izintambo zangaphandle zamukela amajoyinti ekhebula avikelekile, futhi ibhasi lokuxhuma iyunithi elisebenzayo lithatha amabhasi avikelwe. Ngakho-ke, ukuphepha kokusetshenziswa kuthuthukiswa kakhulu, indlela yokusebenza ithatha indlela yasentwasahlobo, futhi impilo yomshini ingaphezu kwezikhathi ezingu-10,000. Idatha yokusebenza kwayo nesimo semishini ingagadwa futhi igadwe ukude, futhi inganakwa. Kuyidivayisi yokusabalalisa amandla enohlobo lokusebenza.

Lawa mayunithi alandelayo angakhethwa kukhabhinethi ukuze akhe iyunithi yokuphakela ugesi eyongayo nesebenzayo:

1. Iyunithi ye-vacuum circuit breaker (630A, 20-25kA)

2. Iyunithi yokushintsha umthwalo we-vacuum (630A, 20-25kA)

 

 

Izici Zomkhiqizo

1. Ukuvikelwa kwemvelo

Zonke izinto ezisetshenziswa ekwenziweni komkhiqizo azinabuthi futhi azinabungozi. I-N2 noma umoya owomile usetshenziswa njengendawo yokuvikela ukushisa ukuze kuncishiswe ukukhishwa kwesisi esibamba ukushisa nokufeza izinjongo zokuvikela imvelo. Azikho izinto ezinobuthi neziyingozi ezikhishwayo ngesikhathi sokusetshenziswa. Ingasetshenziswa kabusha futhi isetshenziswe kabusha, okunquma ukuvikelwa kwemvelo kokusetshenziswa.

2. Uhlu olubanzi lohlelo lokusebenza

Ungasebenzisi noma yimaphi amagesi anobuthi futhi ayingozi, anquma ukuphepha kwendawo yokusetshenziswa. Kungakhathaliseki ukuthi kumagumbi angaphansi, emihubheni, emikhunjini nasezindaweni ezihlukahlukene ngaphakathi nangaphandle. Ingaphakathi lekamelo elinomfutho ophezulu lingagcwaliswa ngomoya owomile noma i-nitrogen, efanele izimo ezinzima ezifana: ukuphakama okuphezulu, umoya onamandla nesihlabathi, izinga lokushisa eliphansi, amakhaza amakhulu, izidingo eziphakeme zokuvikela imvelo, izindawo zokusebenza njalo, ukuphepha. amasayithi angaqhumi, inkungu enosawoti omningi, kanye nokusetshenziswa okuphephile ngaphansi kwezimo zokujiya . Ifakwe ngokugcwele futhi ivalwe ngokugcwele, ifaneleka ukuthi imishini iqhubeke nokusebenza ngemva kokuthatha izinyathelo ezithile zokuhlanza nokomisa ngemva kwesikhathi esifushane sokungena kwamanzi.

3. Ayinasondlo

Ngaphezu komshini wokusebenza, i-GHXH-12 yokuvikela imvelo igesi-insulated main unit series isesimweni esivalwe ngokugcwele, ingxenye yokushintshwa kwe-high-voltage ivalwe ngokuphelele, ukuze kugwenywe ukuhlanzwa nokugcinwa kokunakekelwa, kanye nezindleko ukusebenza nokugcinwa kungancishiswa.

Izinga le-automation ye-switchgear liphezulu kakhulu, futhi umsebenzi wokuthola i-inthanethi uzokwazisa umsebenzisi ngokusebenza kwemishini ngesikhathi sangempela, okulungele kakhulu ukuzenzekelayo kwenethiwekhi yokusabalalisa, ukunciphisa izindleko zokusebenza, futhi kunciphisa izindleko zokukhiqiza zezinkampani zamandla.

4. Ukuvikeleka okuphezulu

Uhlelo oluphelele lokuxhumanisa nokuxhumanisa, ibanga lokuhlukanisa lezigaba ezintathu libonakala ngokucacile, ligwema ukuvela kwezingozi zokusebenzisa kabi. Ukusetshenziswa kwegesi ye-SF6 kukhanseliwe, futhi isakhiwo sokuhlukanisa i-interphase siyaqiniswa ukuze kugwenywe ingozi yokwanda noma yokuqhuma okubangelwa ukujikeleza okufushane phakathi kwezigaba noma amasekhethi amaningi. Isiphazamisi se-vacuum esinamandla e-vacuum ekhabetheni legesi elivikela ukuqhuma kwemvelo siyamukelwa, futhi isigxobo esivalwe ngokuqinile sinokusebenza okwengeziwe kokuvikela kweswishi.

5. Kulula ukusebenza

Iswishi yokunqamula kanye nomhlaba inesibambo esisodwa sokusebenza, futhi asikho isidingo sokukhomba nokukhathazeka ngamaphutha. Uma i-circuit breaker isebenza, isibambo sokusebenza sokunqanyulwa kanye neswishi yomhlaba ayikwazi ukusebenza, futhi ukuqeqeshwa kobuchwepheshe okuyinkimbinkimbi akudingeki, okwenza ukusebenza kube lula kakhulu, ukugwema amaphutha okusebenza.

 

 

Ipharamitha Eyinhloko Yezobuchwepheshe

I-Circuit Breaker Switchgear

Izinto

IyunithiUnit

IpharamithaValues

I-voltage elinganiselwe

kV

12

Isilinganiso sokuvama

Hz

50

Izinga lokwahlukanisa elilinganiselwe

1min imvamisa yamandla imelana ne-voltage

1min imvamisa yamandla imelana ne-voltage

Emhlabeni, isigaba-kuya-isigaba

kV

42

Ngaphesheya kwebanga elihlukanisayo

48

Umfutho wombani umelana ne-voltage (inani eliphakeme)

Umfutho wombani umelana ne-voltage (isiqongo)

Emhlabeni, isigaba-kuya-isigaba

75

Ngaphesheya kwebanga elihlukanisayo

85

Isifunda esisizayo/sokulawula 1min imvamisa yamandla ukumelana ne-voltage (esemhlabeni)

2

Ikalwe okwamanjeIkalwe okwamanje

A

630

Ilinganiselwe isikhathi esifushane ukumelana namanje (inani elisebenzayo)

Ilinganiselwe isikhathi esifushane ukumelana namanje (RMS)

Isekhethi enkulu/iswishi yomhlaba Isekhethi enkulu/iswishi yomhlaba

kA

25/4s

I-Grounding connection circuit I-Grounding connection circuit

21.7/4s

Ilinganiselwe isikhathi esifushane ukumelana namanje (inani eliphakeme)

Ilinganiselwe isikhathi esifushane ukumelana nokwamanje (ukuphakama)

Isekhethi enkulu/iswishi yomhlaba Isekhethi enkulu/iswishi yomhlaba

63

I-Grounding connection circuit I-Grounding connection circuit

54.5

Ilinganiswe ngokuhlukana kwesekethe emfushane kanye nenombolo

kA/izikhathi

25/30

Isekhethi emfishane elinganiselwe yenza isimanje (isiqongo) Ilinganiselwe isekethe emfishane eyenza yamanje (isiqongo)

kA

63

Isilinganiso sokushaja kwekhebula okwamanje

A

25

Kukalwe ngokulandelana kokusebenza kwe-circuit breaker

O-0.3s-CO-180s-CO

Impilo yemishini

Isinqamuli sesekhethi/isinqamuliIsihlukanisi sesekhethi/isinqamuli

izikhathi

10000/3000

Idigri yokuvikelaIdigri yokuvikela

Ithangi legesi elivaliwe

IP67

I-switchgear ebiyelwe

IP4X

i-gas pressuregas pressure

Izinga lokugcwalisa igesi elilinganiselwe (20 ℃, ingcindezi yegeji)

Izinga lokugcwalisa elilinganiselwe ngegesi (20°C, umfutho wegeji)

Mpa

0.02

Izinga elincane lokugcwalisa igesi (20 ℃, ingcindezi yegeji)

I-Gas min. izinga lokugcwalisa (20°C, umfutho wegeji)

0

impahla yokuvala uphawu

Isilinganiso sokuvuza sonyakaIzinga lokuvuza lonyaka

%/ngonyaka

≤0.05

 

Layisha I-Switchgear

Izinto

IyunithiUnit

IpharamithaValues

I-voltage elinganiselwe

kV

12

Isilinganiso sokuvama

Hz

50

Izinga lokwahlukanisa elilinganiselwe

1min imvamisa yamandla imelana ne-voltage

1min imvamisa yamandla imelana ne-voltage

Emhlabeni, isigaba-kuya-isigaba

kV

42

Ngaphesheya kwebanga elihlukanisayo

48

Umfutho wombani umelana ne-voltage (inani eliphakeme)

Umfutho wombani umelana ne-voltage (isiqongo)

Emhlabeni, isigaba-kuya-isigaba

75

Ngaphesheya kwebanga elihlukanisayo

85

Isifunda esisizayo/sokulawula 1min imvamisa yamandla ukumelana ne-voltage (esemhlabeni)

2

Ikalwe okwamanjeIkalwe okwamanje

A

630

Ilinganiselwe isikhathi esifushane ukumelana namanje (inani elisebenzayo)

Ilinganiselwe isikhathi esifushane ukumelana namanje (RMS)

Isekhethi enkulu/iswishi yomhlaba Isekhethi enkulu/iswishi yomhlaba

kA

25/4s

I-Grounding connection circuit I-Grounding connection circuit

21.7/4s

Ilinganiselwe isikhathi esifushane ukumelana namanje (inani eliphakeme)

Ilinganiselwe isikhathi esifushane ukumelana nokwamanje (ukuphakama)

Isekhethi enkulu/iswishi yomhlaba Isekhethi enkulu/iswishi yomhlaba

63

I-Grounding connection circuit I-Grounding connection circuit

54.5

Isifunda esifushane esikalwe ukwenza samanje (isiqongo) Ikalwe isekethe emfushane eyenza yamanje (isiqongo)

Iswishi yokulayisha/iswishi yomhlaba Layisha ukushintsha/iswishi yomhlaba

kA

63

Ilinganiswe ngomthwalo osebenzayo ophukayo Isilinganiso esisebenzayo sokuphuka kwamanje

A

630

Ilinganiswe ngokuphuka kweluphu evaliwe Ilinganiselwe ngokuphuka kweluphu evaliwe

A

630

U-5% ulinganiselwe ngokuphuka komthwalo osebenzayo5% ukalwe ukulayisha okusebenzayo okwamanje

A

31.5

Isilinganiso sokushaja kwekhebula okwamanje

A

2510

ilinganiselwe ngenombolo yokulayisha okusebenzayo

A

100

Iphutha eliyisisekelo liyaphukaUkuphuka kwephutha kwamanje

A/izikhathi

31.5/10

Isekhethi nekhebula lokushaja okwamanje liyaphuka ngaphansi kwesimo sephutha eliphansiIsekhethi kanye nekhebula lokushaja eliphukayo ngaphansi kwesimo sephutha eliphansi

A/izikhathi

17.4/10

Impilo yemishini

Iswishi yokulayisha/iswishi yomhlaba Layisha ukushintsha/iswishi yomhlaba

izikhathi

10000/3000

Idigri yokuvikelaIdigri yokuvikela

Ithangi legesi elivaliwe

IP67

I-switchgear ebiyelwe

IP4X

igesi pressuregas pressure

Izinga lokugcwalisa igesi elilinganiselwe (20 ℃, ingcindezi yegeji)

Izinga lokugcwalisa elilinganiselwe igesi (20°C, umfutho wegeji)

Mpa

0.02

Izinga elincane lokugcwalisa igesi (20 ℃, ingcindezi yegeji)

I-Gas min. izinga lokugcwalisa (20°C, umfutho wegeji)

0

impahla yokuvala uphawu

Isilinganiso sokuvuza sonyakaIzinga lokuvuza lonyaka

%/ngonyaka

≤0.05

 

 

Sebenzisa Izimo

■-25~+45℃;Izinga lokushisa: -25~+45℃;

■ Izinga lokushisa eliphezulu: (24h isilinganiso) +35℃;

■ Isilinganiso somswakama ohlobene (24h): ≤95%;

■ Ukuphakama: ≤1500m;

■ Ikhono lokuzamazama komhlaba: ama-degree angu-8;

■ Idigri yokuvikela: IP67 yokuvala umzimba bukhoma, i-IP4X yokuvalelwa kwe-switchgear;

■ Umoya ozungezile akufanele ngokusobala ungcoliswe igesi evuthayo evuthayo, umhwamuko wamanzi, njll.;

■ Izindawo ezingenakho ukudlidliza okunobudlova okuvamile, kanye nedizayini yokuqina ihlangabezana nezimfuneko ezihlukahlukene ngaphansi kwezimo ezinzima;

■Uma isetshenziswa ngaphansi kwezimo ezijwayelekile zemvelo ezedlula i-GB/T3906, idinga ukuxoxisana.

 


Ikhabhinethi yokuvikela imvelo i-GVH-12


  • Okwedlule:
  • Olandelayo: