I-Gas Insulated Switchgear GRM6-12

Incazelo emfushane:


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

ht

Irobhothi le-Panasonic Welding

gr (1)

Umugqa wokuhlanganisa ithangi likagesi

gr (2)

Isistimu yokuthola ukuvuza kwethangi le-helium

Uhlolojikelele Lomkhiqizo

I-GRM6(XGN □)-12 i-switchgear evalwe ngokugcwele evaleke ngokuphelele, ekwazi ukubona imisebenzi yokulawula, ukuvikela, ukulinganisa, ukuqapha, ukuxhumana, njll. ifaneleka ikakhulukazi izindawo ezinesizinda esincane sokusabalalisa nezidingo ezinokwethenjelwa okuphezulu, nezindawo ezine indawo yemvelo enokhahlo kanye nezimo, njengendawo engaphansi komhlaba, izindawo eziphakeme nezisogwini. Isetshenziswa kakhulu ezindaweni lapho umhlaba uminyene khona nendawo ilinganiselwe, kudingeka ukwethembeka okuphezulu, njengamabhizinisi ezimboni nezimayini kanye neziteshi ezincane, imizila ehamba ngaphansi, izitimela ezilula, njll.

Ihlanganisa ubuchwepheshe be-microprocessor, ubuchwepheshe besimanje bokuxhumana kwenethiwekhi kanye nobuchwepheshe obusha bokukhiqiza amaswishi ukuze kuhlukanise ngempumelelo futhi kuhlanganiswe umthwalo wamanje kanye nomjikelezo omfushane wamanje. Ukulawulwa kokuvikela ukulinganisa nemisebenzi yokuxhumana elungiselelwe ngaphakathi kwedivayisi ingahlangabezana ngokugcwele nezimfuneko zohlelo oluzenzakalelayo lokusabalalisa.

Izingxenye ze-conductive zezingxenye zamandla kagesi aphezulu njengezinqamuli zesekethe, amaswishi amathathu ezindawo zokusebenza kanye namaswishi ekhefu lokulayisha kusekethe eyinhloko kufakwa egodini lensimbi elivaliwe lohlobo lwekhabhinethi. Isici esikhulu kunazo zonke ukuthi asithinteki imvelo yangaphandle, futhi inokwethenjelwa okuphezulu futhi ingenza imishini isebenze ngokuphepha isikhathi eside ezindaweni ezinemvelo empofu; okwesibili, ubukhulu bengxenye ye-voltage ephezulu buncishisiwe, idivayisi yenziwe i-miniaturized, futhi izingxenye ezingaphakathi kwe-casing evaliwe azinakho ukugqwala nokugqwala, ngaleyo ndlela kuqedwe ithonya. Ngaphezu kwalokho, ngezingxenye zamandla kagesi aphezulu ngokusebenza okuzinzile nempilo ende kagesi, izidingo zokulungisa noma ukunakekelwa okuncane zingafinyelelwa.

Uhlobo Incazelo

Sebenzisa Izimo

Izinga lokushisa lomoya elizungezile: -40℃~+40℃;

Umswakama womoya ohlobene: isilinganiso sansuku zonke ≤95%, isilinganiso sanyanga zonke ≤90%;

Ukuphakama ≤1500m (ngaphansi kwengcindezi evamile yokwehla kwamandla emali);

Ukuqina kokuzamazama komhlaba ≤9 ikilasi;

Izindawo ezingenawo umlilo, ukuqhuma, ukungcola okubi kakhulu, ukugqwala kwamakhemikhali nokudlidliza okukhulu.

Izimo ezikhethekile

Abakhiqizi nabasebenzisi bokugcina kufanele bavumelane ngezimo ezikhethekile zokusebenza ezehlukile ezimweni ezijwayelekile zokusebenza;

Uma kuhileleke indawo yokusebenza enokhahlo, umkhiqizi kanye nomphakeli kufanele kukhulunywe nabo;

Uma imishini kagesi ifakwe endaweni ephakeme ngamamitha angu-1500 noma ngaphezulu, imiyalelo ekhethekile iyadingeka ukuze kulungiswe ukucindezela ngesikhathi sokukhiqiza. Lapho ukucindezela kulungiswa, impilo ye-switchgear ngokwayo ayinawo umphumela obalulekile.

Izici Zobuchwepheshe Zomkhiqizo

Umklamo we-modular

Iswishi ihlukaniswe yaba imojula engaguquki kanye neqembu lemojula elinwebekayo. Egunjini elifanayo le-SF6 le-insulated air, amamojula angafika ku-6 angalungiswa. Ukushintsha amakhabethe anamamojula angaphezu kuka-6 kufanele kuxhunywe nebha yokunweba ukuze kuqhamuke i-semi-module. Isakhiwo; ukucushwa kwemojula okugcwele kungafinyelelwa ngokusebenzisa ibhasi elinwetshiwe phakathi kwawo wonke amamojula. Ngokuhlanganiswa kwamamojula ahlukene asebenzayo, uhlelo lokusabalalisa amandla olulula kuya kokuyinkimbinkimbi lungakhiwa ukuze kuhlangatshezwane nezidingo zokucushwa ezihlukahlukene esiteshini esincane sesibili kanye nokuvula nokuvala.

Isakhiwo esihlangene

Ngaphandle kwekhabhinethi yemitha ye-air-insulated, wonke amamojula angama-325mm ububanzi futhi ububanzi bekhabhinethi yokulinganisa bungama-695mm; amalunga ekhebula awo wonke amayunithi anobude obufanayo phansi, okulungele ukwakhiwa endaweni.

Akuthintwa imvelo

Zonke izingxenye ezibukhoma ezinamandla amakhulu zifakwe kukesi lensimbi engenasici elivaliwe. Ikesi lishiselwe ngepuleti lensimbi engagqwali futhi ligcwaliswe ngegesi ye-SF6 ngengcindezi yokusebenza ye-1.4 bar. Izinga lokuvikela yi-IP67. Ingasetshenziswa ezindaweni lapho ifakwe khona endaweni emanzi, enothuli, emfuthweni kasawoti, emayini, esiteshini esincane sohlobo lwebhokisi kanye nokungcoliswa komoya. Ngisho nekhompathimenti ye-fuse inesilinganiso se-IP67. Amabhasi okunweba avikelwe ngokuphelele futhi avikelwe ukuze kuqinisekiswe ukuthi awathintwa izinguquko endaweni yangaphandle.

Ukuphepha komuntu siqu okuthembekile kakhulu

Zonke izingxenye ezibukhoma zivalelwe egumbini lomoya le-SF6; ukushintshwa kunomzila othembekile wokusiza ingcindezi, ukushintshwa komthwalo kanye nokumisa phansi kukhona ukushintshwa kwezikhundla ezintathu, okwenza kube lula ukuxhuma phakathi komunye nomunye; Ukuxhuma okuthembekile komshini phakathi kwekhava yekhompathi yekhebula kanye neswishi yokulayisha .

Inkomba yokusebenza

● Ingcindezi yegesi ye-SF6: 1.4bar ngaphansi kuka-20℃ (ingcindezi ephelele)

● Izinga lokuvuza lonyaka: 0.25%/ngonyaka

● Ibanga lokuvikela

Igumbi legesi le-SF6: IP67

Ishubhu ye-Fuse: IP67

I-switchgear ebiyelwe: IP3X

● Ibha yebhasi

I-switchgear yebhasi yangaphakathi: 400mm2Nge

I-switchgear earthing busbar: 150mm2Nge

Ubukhulu begumbi legesi ebiyelwe ngensimbi engagqwali: 3.0mm

● Iphaneli yangaphambili kanye nephaneli eseceleni ye-switchgear, kanye nesembozo sangaphambili segumbi lekhebula, umbala ojwayelekile wenkampani: umbala we-jade 7783; uma abasebenzisi benezidingo ezikhethekile, sicela ubeke phambili lapho u-oda.

Hlangana neZimiso Eziyinhloko

• I-GB 1984 High-voltage alternating-current circuit-breakers (IEC 62271-100: 2001, MOD)

• I-GB 1985 High-voltage alternating-current disconnectors namaswishi omhlaba (IEC 62271-102: 2002, MOD)

• I-GB/T 11022 Ukucaciswa okujwayelekile kwegiya elinamandla kagesi namazinga okulawula

• I-GB 3804 High-voltage alternating-current switch yevoltage elinganiselwe ngaphezulu kuka-3.6kV nangaphansi kuka-40.5kV (IEC 60265-1-1998, MOD)

• I-GB 3906 I-Alternating-current metal-enclosed switchgear kanye negiya lokulawula lamandla kagesi akalwe ngaphezu kuka-3.6kV nokufika futhi ahlanganise 40.5kV (IEC 62271-200-2003, MOD)

• I-GB 4208 Degrees of protection ihlinzekwa nge-enclosure (IPcode) (IEC 60529-2001, IDT)

• I-GB 16926 High-voltage eshintshashintshayo yamanje inhlanganisela ye-switch-fuse (IEC 6227-105-2002, MOD)

• I-DL/T 402 Ukucaciswa kwama-high-voltage alternating-current circuit-breakers (IEC 62271-100-2001, MOD)

•DL/T 403 HV vacuum circuit-breaker yevoltage elinganiselwe engu-12kv ukuya ku-40.5kv

• I-DL/T 404 I-alternating-current metal-enclosed switchgear kanye negiya lokulawula lamandla kagesi akalwe ngaphezu kuka-3.6kV futhi afika futhi ahlanganise no-40.5kV

• Izinqamuleli ze-DL/T 486 HV AC namaswishi omhlaba (IEC 62271-102-2002, MOD)

• I-DL/T 593 Ukucaciswa okujwayelekile kwe-switchgear ene-voltage ephezulu namazinga okulawula i-IEC 60694-2002, MOD)

• I-DL/T 728 Umhlahlandlela wobuchwepheshe we-oda le-gas-insulated metal-enclosed switchgear (IEC 815-1986, IEC 859-1986)

• I-DL/T 791 Ukucaciswa kwephaneli ye-switchgear egcwele igesi ye-AC HV

Imingcele Eyinhloko Yezobuchwepheshe

CHA.

Izinto

Iyunithi

Inani

Layisha ikhefu switch

Inhlanganisela

Vacuum circuit breaker

Nqamula/

ukushintshwa komhlaba

1

I-voltage elinganiselwe

kV

12

2

Isilinganiso sokuvama

Hz

50

3

Imvamisa yamandla imelana ne-voltage (isigaba-kuya-isigaba/kubo bonke abathintwayo abavuliwe)

kV

42/48

4

Umfutho wombani umelana ne-voltage (isigaba-kuya-isigaba/kuzo zonke izindawo ezivulekile oxhumana nabo)

kV

75/85

5

Ikalwe okwamanje

A

630

Bheka inothi 1

630

630

6

Ilinganiselwe ngokuphuka kweluphu evaliwe

A

630

7

Isilinganiso sokushaja kwekhebula okwamanje

A

10

8

Ilinganiselwe isekethe emfishane eyenza yamanje (isiqongo)

kA

50

80

50

9

Isilinganiso esiphakeme sokumelana nokumelana namanje

kA

50

10

Ilinganiselwe isikhathi esifushane ukumelana namanje

kA/4s

20

11

Ilinganiselwe isekethi emfushane yamanje

kA

31.5

20

12

Isilinganiso sokudlulisa samanje

A

1700

13

Ubukhulu. umsinga we-fuse ehlonyelwe

A

125

14

Ukumelana nesifunda

≤300

≤600

≤300

15

Impilo yemishini

izikhathi

5000

3000

5000

2000

Qaphela 1: kuncike kumanje olinganiselwe we-fuse.

Uku-oda Iziyalezo

Lapho u-oda, ulwazi olulandelayo lobuchwepheshe kufanele lunikezwe

Umdwebo oyinhloko wesifunda, umdwebo wokuhlelwa, nomdwebo wesakhiwo;

I-switchgear yesibili yesifunda somdwebo womdwebo;

• Uma i-switchgear isetshenziswa ngaphansi kwezimo ezikhethekile zemvelo, kufanele iphakanyiswe.

Amamojula Ajwayelekile

Imojula ngayinye ye-GRM6(XGN □)-12 yohlobo lwe-switchgear inokucushwa okulandelayo

• Bona ukucushwa okujwayelekile nezici "kumojula yokuxhuma ikhebula ngaphandle kommese waphansi"

• Ikhabhinethi ye-C - imojuli yokushintsha ukulayisha

Bona ukucushwa okujwayelekile nezici "kumodule yokushintsha umthwalo"

•Bona ukucushwa okujwayelekile nezici "ku-load switch kanye nemojula yenhlanganisela ye-fuse"

• Ikhabhinethi ye-V - imojuli ye-vacuum switch

Bona ukucushwa okujwayelekile nezici "kumojula ye-vacuum switch"

• Inkomba ye-Capacitive voltage ye-bushing engenayo

• Faka igeji yokucindezela eqapha ukuminyana kwe-SF6 ekamelweni ngalinye

• Isikhwama sokuphakamisa

• Isibambo sokusebenza

Ukucushwa Ongakukhethas

Indlela yokusebenza kagesi/ikhebula elifushane kanye nenkomba yephutha eliphansi/i-transformer yamanje nemitha

iht (1) iht (2) iht (3) ihrt (4) iht (5)

Imojula Yokunweba Ejwayelekiles

Amamojula atholakalayo

C Layisha switch module

Ububanzi=325mm

D Imojula yokuxhuma ikhebula ngaphandle kommese ophansi

Ububanzi=325mm

F Layisha inhlanganisela ye-fuse module kagesi

Ububanzi=325mm

IN Imodyuli ye-vacuum circuit breaker

Ububanzi=325mm

SL Imojula yokushintsha ingxenye yebhasi (i-load switch)

Ububanzi=325mm

Phendula Imojula yokushintsha ingxenye yebhasi (i-vacuum circuit breaker)
SINihlale inemojula yokuphakamisa ibhasi

Ububanzi=650mm

M Imojula yemitha 12kV

Ububanzi=695mm

I-PT Imojuli

Ububanzi=370 noma 695mm

Qaphela: Imojuli eyodwa kufanele yengeze isandiso ngaphambi kokuthi isetshenziswe.

i-ht (1) ht (2) ht (3)

imakethe

C Imojula Yokunweba-Umthwalo Wokushintsha Imojuli C

Ukucushwa Okujwayelekile kanye Nezimpawu

• 630A ibhasi yangaphakathi

• Umthwalo wendawo yokusebenza emithathu/iswishi yomhlaba

• Indlela yokusebenza ye-single-spring emithathu enendawo yokusebenza eyodwa, eneswishi emibili yokulayisha ezimele kanye namashafti asebenzayo weswishi yomhlaba

• Inkomba yokushintsha ukulayisha kanye nendawo yokushintsha umhlaba

• Ihlathi eliphumayo ngaphambi kokuhlelwa okuvundlile, 630A 400 uchungechunge lwe-bolted bushing

• Inkomba ye-Capacitive voltage ekhombisa ukuthi i-bushing ibukhoma

• Kuyo yonke imisebenzi yeswishi, kukhona ingidi ye-add-on elula kuphaneli

• Igeji yegesi ye-SF6 (igeji eyodwa kuphela ebhokisini legesi le-SF6)

• Ibha yebhasi ephansi

• Ukuxhumanisa komhlaba shintshela kuphaneli yangaphambili yekhompathimenti yekhebula

Ukucushwa Ongakukhetha kanye Nezimpawu

• Isandiso sebhasi esigodliwe

• Ibhasi yangaphandle

• 110V/220V DC/AC

Layisha switch operation motor 110V/220V DC/AC

• Isekhethi emfishane kanye nesikhombi sephutha lomhlaba

• Kala i-toroidal transformer yamanje kanye ne-ammeter

• Imitha ye-toroidal current transformer kanye nemitha yehora le-watt

• Isibambisi sombani noma i-double cable head ingafakwa ku-cable bushing engenayo

• Ukuhlanganisa ukhiye

• Isikhiya sesisekelo esibukhoma esingenayo (khiya iswishi yomhlaba lapho isihlahla sisebenza) 110V/220VAC

• Oxhumana nabo abasizayo

2NO+2NC Layisha shintsha isikhundla 2NO+2NC

2NO+2NC Indawo yokushintsha umhlaba 2NO+2NC

1 CHA Igeji yokucindezela enesignali 1 NO

1 AKEKHO isicishamlilo se-Arc esithintana nesignali 1 NO

• Idivayisi yesibili ingafakwa

Igumbi lomugqa wesibili phezulu kwe-switchgear

Ibhokisi le-voltage ephansi phezulu kwe-switchgear

Imojula Yokunweba-Ngaphandle Kommese Wokumisa Imojula D

Ukucushwa Okujwayelekile kanye Nezimpawu

• 630A ibhasi yangaphakathi

• Ihlathi eliphumayo ngaphambi kokuhlelwa okuvundlile, 630A 400 uchungechunge lwe-bolted bushing

• Inkomba ye-Capacitive voltage ekhombisa ukuthi i-bushing ibukhoma

• Igeji yegesi ye-SF6 (igeji eyodwa kuphela ebhokisini legesi le-SF6)

• Ibha yebhasi ephansi

Ukucushwa Ongakukhetha kanye Nezimpawu

• Isandiso sebhasi esigodliwe

• Ibhasi yangaphandle

• Isekhethi emfishane kanye nesikhombi sephutha lomhlaba

• Kala i-toroidal transformer yamanje kanye ne-ammeter

• Imitha ye-toroidal current transformer kanye nemitha yehora le-watt

• Isibambisi sombani noma i-double cable head ingafakwa ku-cable bushing engenayo

• Idivayisi yesibili ingafakwa

Igumbi lomugqa wesibili phezulu kwe-switchgear

Ibhokisi le-voltage ephansi phezulu kwe-switchgear

svv
dv

Ukushintsha Kwemojula Yokunweba kanye Nenhlanganisela Yemojuli F

Ukucushwa Okujwayelekile kanye Nezimpawu

• 630A ibhasi yangaphakathi

• Iswishi yokulayisha indawo yokusebenza emithathu, isiphetho sekhanda se-fuse sixhunywa ngomshini neswishi yomhlaba yomsila womsila.

• Indlela yokusebenza ye-double-spring enendawo yokusebenza emithathu, eneswishi yokulayisha emibili ezimele kanye namashafu okusebenza amaswishi yomhlaba

• Inkomba yokushintsha ukulayisha kanye nendawo yokushintsha umhlaba

• I-Fuse tube

• I-Fuse ibekwe ngokuvundlile

• Inkomba yokugibela i-fuse

• Ukuphuma kwehlathi kulungiselelo oluvundlile ngaphambili, 200A 200 series plug-in bushing

• Inkomba ye-Capacitive voltage ekhombisa ukuthi i-bushing ibukhoma

• Kuyo yonke imisebenzi yeswishi, kukhona ingidi ye-add-on elula kuphaneli

• Igeji yegesi ye-SF6 (igeji eyodwa kuphela ebhokisini legesi le-SF6)

• Ibha yebhasi ephansi

• Amafuse epharamitha yokuvikela i-transformer

12kV ubukhulu. 125A fuse

• Ukuxhumanisa komhlaba shintshela kuphaneli yangaphambili yekhompathimenti yekhebula

Ukucushwa Ongakukhetha kanye Nezimpawu

• Isandiso sebhasi esigodliwe

• Ibhasi yangaphandle

• Layisha switch operation motor 110/220V DC/AC

• Ikhoyili ehambayo ehambisanayo 110/220V DC/AC

• Ikhoyili yokuvala ehambisanayo 110/220V DC/AC

• Kala i-toroidal transformer yamanje kanye ne-ammeter

• Imitha ye-toroidal current transformer kanye nemitha yehora le-watt

• Isikhiya sesisekelo esibukhoma esingenayo (khiya iswishi yomhlaba lapho isihlahla sisebenza) 110V/220VAC

• Oxhumana nabo abasizayo

Layisha indawo yokushintsha 2NO+2NC

Indawo yokushintsha umhlaba 2NO+2NC

Igeji yokucindezela enesignali engu-1 NO

I-Fuse evuthelwe ngu-1 NO

• Idivayisi yesibili ingafakwa

Igumbi lomugqa wesibili phezulu kwe-switchgear

Ibhokisi le-voltage ephansi phezulu kwe-switchgear

Imojuli Yokunweba Yemojuli Yebhasari Yokushintsha (I-Circuit Breaker) SphakathiBr

Ukucushwa Okujwayelekile kanye Nezimpawu

• 630A ibhasi yangaphakathi

• I-630A i-vacuum circuit breaker

• Imishini emibili yokusebenza ye-double-spring ye-vacuum circuit breaker

• Iswishi yokunqamula i-vacuum circuit breaker

• Nqamula indlela yokusebenza yeswishi yentwasahlobo eyodwa

• Ukuxhuma ngomshini kwe-vacuum circuit breaker kanye neswishi yokunqamula

• Vacuum circuit breaker futhi unqamule inkomba yendawo yokushintsha

• Kuyo yonke imisebenzi yeswishi, kukhona ingidi ye-add-on elula kuphaneli

• Igeji yegesi ye-SF6 (igeji eyodwa kuphela ebhokisini legesi le-SF6)

• I-SV ihlale ixhunywe ku-switchgear yebhasi, ethatha amamojula amabili ububanzi ndawonye

Ukucushwa Ongakukhetha kanye Nezimpawu

• Isandiso sebhasi esigodliwe

• Ibhasi yangaphandle

• Vacuum circuit breaker operation motor 110V/220V DC/AC

• Ikhoyili ehambayo ehambisanayo 110/220V DC/AC

• Ikhoyili yokuvala ehambisanayo 110/220V DC/AC

• Ukuhlanganisa ukhiye

• Oxhumana nabo abasizayo

Indawo ye-circuit breaker 2NO+2NC

Nqamula isikhundla sokushintsha 2NO+2NC

• Idivayisi yesibili ingafakwa

Igumbi lomugqa wesibili phezulu kwe-switchgear

Ibhokisi le-voltage ephansi phezulu kwe-switchgear

svv
sd

Imojula Yokunweba ye-V - Imojuli V ye-Vacuum Circuit Breaker

Ukucushwa Okujwayelekile kanye Nezimpawu

• 630A ibhasi yangaphakathi

• 630A i-transformer/line protection vacuum breaker yesekethe

• Imishini emibili yokusebenza ye-double-spring ye-vacuum circuit breaker

• I-vacuum circuit breaker yehlisa kathathu indawo yokusebenza nqamula/iswishi yomhlaba

• Ukunqamula indawo yokusebenza emithathu/ukushintsha indlela yokusebenza kwentwasahlobo eyodwa

• Ukuxhuma ngomshini kwe-vacuum circuit breaker kanye neswishi emithathu yendawo yokusebenza

• I-vacuum circuit breaker kanye nenkomba yokushintsha indawo yokusebenza emithathu

• Ukudluliselwa kokuvikela ngogesi

• Ikhoyili yohambo (yesenzo sokudlulisa)

• Ihlathi eliphumayo ngaphambi kokuhlelwa okuvundlile, 630A 400 uchungechunge lwe-bolted bushing

• Inkomba ye-Capacitive voltage ekhombisa ukuthi i-bushing ibukhoma

• Kuyo yonke imisebenzi yeswishi, kukhona ingidi ye-add-on elula kuphaneli

• Igeji yegesi ye-SF6 (igeji eyodwa kuphela ebhokisini legesi le-SF6)

• Ibha yebhasi ephansi

• Ukuxhumanisa komhlaba shintshela kuphaneli yangaphambili yekhompathimenti yekhebula

Ukucushwa Ongakukhetha kanye Nezimpawu

• Isandiso sebhasi esigodliwe

• Ibhasi yangaphandle

• Vacuum circuit breaker operation motor 110V/220V DC/AC

• Ikhoyili ehambayo ehambisanayo 110/220V DC/AC

• Ikhoyili yokuvala ehambisanayo 110/220V DC/AC

• Kala i-toroidal transformer yamanje kanye ne-ammeter

• Imitha ye-toroidal current transformer kanye nemitha yehora le-watt

• Isikhiya sesisekelo esibukhoma esingenayo (khiya iswishi yomhlaba lapho isihlahla sisebenza) 110V/220V AC

• Ukuhlanganisa ukhiye

• Oxhumana nabo abasizayo

Isikhundla sokushintsha i-vacuum 2NO+2NC

Nqamula isikhundla sokushintsha 2NO+2NC

Indawo yokushintsha umhlaba 2NO+2NC

Isignali yohambo lwe-vacuum switch 1 NO

Igeji yokucindezela enesignali engu-1 NO

• Idivayisi yesibili ingafakwa

Igumbi lomugqa wesibili phezulu kwe-switchgear

Ibhokisi le-voltage ephansi phezulu kwe-switchgear

• I-SPAJ140C Okunye ukudluliselwa okufana ne-SPAJ140C

Imojula Yokunweba-Ibha Yebhasi Yengxenye Yokushintsha Imojuli (Ukushintsha Ukulayisha)SL

Ukucushwa Okujwayelekile kanye Nezimpawu

• 630A ibhasi yangaphakathi

• Nqamula iswishi

• Indlela yokusebenza yentwasahlobo eyodwa

• Shintsha inkomba yendawo

• Kuyo yonke imisebenzi yeswishi, kukhona ingidi ye-add-on elula kuphaneli

• Igeji yegesi ye-SF6 (igeji eyodwa kuphela ebhokisini legesi le-SF6)

Ukucushwa Ongakukhetha kanye Nezimpawu

• Isandiso sebhasi esigodliwe

• Ibhasi yangaphandle

• Layisha switch operation motor 110V/220V DC/AC

• Ukuhlanganisa ukhiye

• Oxhumana nabo abasizayo

Layisha indawo yokushintsha 2NO+2NC

• Idivayisi yesibili ingafakwa

Igumbi lomugqa wesibili phezulu kwe-switchgear

Ibhokisi le-voltage ephansi phezulu kwe-switchgear

wef
kabi

IKhabhinethi Yokunwetshwa Kwemitha ye-Module-12kV

Ukucushwa Okujwayelekile kanye Nezimpawu

• 2pcs transformer zamanje

• 2pcs voltage transformers

• I-Fuse yokuvikela i-PT

• Izingxenye zamandla kagesi aphansi

I-Voltmeter

I-Ammeter

WxHxD=695x1334x820mm

WxHxD=695x1680x820mm(nebhokisi lezinsimbi)

Ukucushwa Ongakukhetha kanye Nezimpawu

• Isibambi se-zinc oxide

• Inkomba ye-Capacitive voltage ekhombisa ukuthi i-switchgear ifakwe ugesi

• Izingxenye zamandla kagesi aphansi

1pc imitha yehora le-watt esebenzayo

1pc imitha yehora le-watt esebenzayo

IKhabhinethi Yokunwetshwa Kwemojuli ye-12kV Voltage Transformer

Ukucushwa Okujwayelekile kanye Nezimpawu

• 1pc noma 2pcs voltage transformer

• I-Fuse yokuvikela i-PT

• I-Voltmeter

WxHxD=695x1334x820mm

WxHxD=695x1680x820mm (enebhokisi lezinsimbi)

Ukucushwa Ongakukhetha kanye Nezimpawu

• Isibambi se-zinc oxide (695 ububanzi)

• Inkomba ye-Capacitive voltage ekhombisa ukuthi i-switchgear ifakwe ugesi

wena

Okungenayo / Ukuvikelwa Komugqa Ophumayo

Sebenzisa i-vacuum switch / vacuum circuit breaker module

I-transformer noma isivikelo somugqa i-vacuum switch/vacuum circuit breaker, ene-relay evikelayo nama-transformer amanje. Uma iphutha lamanje lifinyelela ukulungiselelwa kwamanje okusethwe yi-relay yokuvikela, i-relay yokuvikela ikhipha umyalo wokugoqa iswishi ngeyunithi yohambo.

◆ Transformer / Line Ukuvikelwa

I-GRM6-12 C-GIS ihlinzeka ngezinhlobo ezimbili zokuvikela i-transformer: inhlanganisela ye-fuse switch switch kanye ne-circuit breaker enokuvikelwa kwe-relay.

Sebenzisa Imojula Yokuhlanganisa Ukushintsha Kwe-Fuse

Ukuvikelwa kwe-Transformer kuyinhlanganisela yamanje ekhawula i-fuse yamandla kagesi aphezulu kanye nokushintshwa komthwalo. Ikhompathimenti ye-fuse izofakwa ngemuva kwendawo ebiyelwe ehlukile, ecijile ngaphambili kweyunithi. Iswishi yokulayisha isebenzisa indlela yokushaja yasentwasahlobo engase iqaliswe isigadli se-fuse. Ukuze kube lula ukushintshwa kwe-fuse, isibambo sokusebenza singasetshenziswa ukususa isiphetho se-fuse compartment. Indlela yohambo yefuse ibekwe ngaphambili ukuze kuqinisekiswe ukusebenza okungangeni kwamanzi kwalo lonke uhlelo. Inhlanganisela ye-fuse yeswishi yokulayisha isebenzisa uhlobo olulayishwe intwasahlobo lwe-fuse yamanje ekhawulela uhlobo lokuvikela-ukuvikela, futhi uhlangothi lwesigadli lubheke phambili kwe-switchgear phakathi nokufakwa.

◆ Ithebula lokuqhathanisa le-Fuse-Transformer

rt

◆Imiyalelo yokuhlela

Hlela i-CCF+ engu-1

• Ulayini ongenayo ufakwe isibambisi sombani futhi unesandiso esigodliwe

iht (1)

Hlela 2 CCFFF=CF

• Isethi e-1 kumayunithi amaningi angu-5, amayunithi angaphezu kwama-5 adinga ukunweba uxhumo lwebhasi

 iht (2)

Hlela 3 VV=M=FFF

• Isilinganiso sohlangothi lwe-voltage ephezulu

 iht (3)

Hlela 4 PT=FF=FCSLCF=FF=PT

• Ingxenye yebha yebhasi eyodwa ene-busbar PT

ihrt (4)

iht (5)

Isijobelelo

1.Oxhumana nabo abasizayo

2 CHA + 2 NC izikhundla zokushintsha inkomba ziyatholakala kuwo wonke ama-switch switch nama-circuit breaker. Ikhoyili yohambo oluhambisanayo (AC noma i-DC) ingagxunyekwa ku-transformer/switch breaker. Iyunithi yokulawula ye-LV itholakala ngemuva kwephaneli yangaphambili.

2.Voltage inkomba

Inkomba ye-capacitive voltage ikhombisa ukuthi i-bushing inamandla futhi isokhethi ekuyo ingasetshenziselwa isigaba senuzi.

3.Isekhethi emfishane / inkomba yephutha lomhlaba

Ukuze kube lula indawo yephutha, imojula yokushintsha ikhebula ingafakwa isibonisi esifushane/iphutha eliphansi ukuze kutholakale iphutha elilula.

4.Ukusebenza kukagesi

Ukusebenza ngesandla kweyunithi yokushintsha ikhebula kanye neyunithi ye-transformer kuyisixazululo esijwayelekile. Kungenzeka futhi ukufaka umshini wokusebenza kagesi. Iswishi yekhebula, i-vacuum circuit breaker, neswishi yomhlaba kusetshenziswa umshini otholakala ngemuva kwephaneli yangaphambili. Wonke ama-switch kanye nama-circuit breaker angasetshenziswa ngokusebenzisa isibambo (ukucushwa okujwayelekile) noma angahlonyiswa nge-motor operating mechanism (i-accessory). Kodwa-ke, ukushintshwa komhlaba kungenziwa kuphela ngesandla futhi kufakwe umshini onamandla okuvala amandla akhona. Izindlela zokusebenza zikagesi kulula ukuzisebenzisa ngezigaba.

5.Uxhumano lwekhebula

I-GRM6(XGN □)-12 switchgear ifakwe izihlahla ezijwayelekile. Wonke ama-bushings anobude obufanayo ukusuka phansi futhi avikelwe isembozo sekhebula lendawo. Lesi simbozo singahlanganiswa neswishi yomhlaba. Okungenani kwamakhebula amabili angenayo, ikhava yekhompathimenti yamakhebula amabili ezinikele nayo ingasetshenziswa.

6.Inkomba yengcindezi

Ngokuvamile ifakwe inkomba yokucindezela, le nkomba isesimweni segeji yokucindezela. Izinto ezithinta ugesi nazo zinganikezwa ukukhombisa ukwehla kwengcindezi.

7.Ibha yebhasi yangaphandle

I-GRM6(XGN □)-12 switchgear ingafakwa ibha yebhasi yangaphandle enesilinganiso samanje esingu-1250A.

8.Igumbi lomugqa wesibili / ibhokisi le-voltage ephansi

I-GRM6 (XGN □)-12 switchgear ingahlonyiswa ngendawo yesibili yomugqa noma ibhokisi le-voltage ephansi phezulu kwe-switchgear. Ikhompathimenti yomugqa wesibili isetshenziselwa ukufaka i-ammeter (noma ngaphandle kwe-switch switch) kanye neyunithi yokulawula yokuvimbela bukhoma. Ibhokisi le-voltage ephansi lisetshenziselwa ukufaka ama-relay afana ne-SPAJ140C, REF, futhi lingabuye lifakwe i-ammeter (noma ngaphandle kwe-switchover switch) kanye neyunithi yokulawula yokuvimbela bukhoma.

9.Isibambi sombani

Imojula yekhebula engenayo/ephumayo ye-GRM6(XGN □)-12 uhlobo lokushintsha igiya ingafakwa isibambisi sombani se-zinc oxide kukhebula; i-zinc oxide lightning arrester ingafakwa futhi kubha yebhasi noma kukhabhinethi ye-M.

I-GRM6(XGN)-12 Umdwebo Wesakhiwo Se-switchgear

1. Igumbi lekhebula

2. Inkomba ye-Fuse blow

3. Igumbi le-fuse

4. Igumbi lokufaka

5. isibonisi esishajiwe

6. Inkomba yengcindezi

7. Idivayisi yokukhiya kuphaneli

8. Imbobo yokusebenza yokushintsha komhlaba

9.Layisha imbobo yokusebenza yokushintsha

10. Umdwebo wesifunda se-analog

11. Inkinobho yokuvula

12. Inkinobho yokuvala

13. Imbobo yokusebenza kwe-circuit breaker

14.Nqamula umdwebo wesisekelo sembobo yeswishi

svv

◆ GRM6(XGN)-12Isakhiwo se-switchgear kanye nobukhulu

iht (1)

Umdwebo Wesisekelo

1.Iyunithi ejwayelekile

iht (2)

Umdwebo Wesisekelo

2.Ikhabethe lamamitha angu-10kV

iht (3)

Ukubuka okuphezulu kwensimbi yesisekelo sesiteshi lapho ikhabhinethi ye-GRM6(XGN □)-12 ixhunywe kukhabhinethi engu-10kV M noma iKhabhinethi ye-PT

ihrt (4)

Umdwebo wesisekelo we-GRM6(XGN □)-12 wekhabhinethi exhunywe kukhabhinethi engu-10kV M noma ikhabethe le-PT

Uhlolojikelele

I-C-type yokusebenza kwentwasahlobo ye-GRM6-12 i-switchgear yenethiwekhi eyindandatho evalekile egcwele igesi iyithuluzi lokumisa leswishi evalekile yensimbi elinganiselwe engu-12kV AC. Lolu chungechunge lwezindlela zisebenzisa i-planar scroll spring charge ukulawula isenzo seswishi yokulayisha kanye nokusebenza kwaphansi Ukulawula ukushaja kokuminyanisa kwentwasahlobo ngaphezulu kwaphakathi nendawo. Indawo yokusebenza inezindawo ezintathu zokusebenza: ukuvala, ukuvulwa, nokubeka phansi. Lolu chungechunge lwemikhiqizo lunomsebenzi wokuhlanganisa okuvimbelayo okuhlanu, usayizi omncane, ukufakwa okulula nokuvumelana nezimo okuqinile.

Umkhiqizo uhlolwa ngokugcwele futhi uphasiswe ngaphambi kokulethwa, ngokuhambisana nezidingo ezifanele ze-GB3804-2004 "amaswishi ashintshashintshayo-amanje aphezulu ku-voltage elinganiselwe ngaphezulu kuka-3.6kV nangaphansi kuka-40.5kV", GB3906-2006 "insimbi yamanje-eshintshanayo- i-switchgear evaliwe kanye ne-controlgear ye-voltage elinganiselwe ngaphezulu kuka-3.6kV futhi ifika futhi ihlanganise no-40.5kV", GB16926-2009 "izinhlanganisela ze-switch-fuse ezishintshashintshayo zamanje ezinamandla aphezulu".

frht

indlela yokusebenza kagesi engenayo

Uhlobo Incazelo

sd

I-Mechanism voltage: DC/AC220V, 110V, 48V, 24V

Uhlobo lwe-Mechanism: I-J-incoming mechanism,

I-C-outgoing mechanism (nohambo lwe-fuse)

Imodi yokusebenza: I-D-electric operation,S-manual operation

imakethe

indlela yokusebenza engenayo mathupha

Imiyalo Yokusebenza ye-Spring Mechanism

● Umsebenzi wokuvala:

Hlola ukuthi umkhiqizo ukhubazekile yini ngesikhathi sokuthutha. Faka futhi ulungise indlela ekushintsheni kokulayisha. Sebenzisa isibambo sokusebenza esikhethekile ukuze usifake engxenyeni engenhla yomshini bese uyizungezisa ngamadigri angu-90 ngokwewashi. I-switch switch ivala isifunda esikhulu ngaphansi kwesenzo samandla entwasahlobo we-mechanical. Noma ukusebenza kukagesi, cindezela inkinobho yokuvala futhi injini ishayela umshini wokuqedela umsebenzi wokuvala ukushintshwa, ngalesi sikhathi umsebenzi wokumisa phansi awukwazi ukwenziwa.

● Umsebenzi wokuvula:

Faka isibambo sokusebenza engxenyeni engenhla yendlela bese uyizungezisa ngokuphikisana newashi cishe ngamadigri angu-90. Ukushintsha komthwalo kuvula isifunda esikhulu ngaphansi kwesenzo samandla entwasahlobo we-mechanical. Noma cindezela inkinobho yokuvula ngesikhathi sokusebenza kukagesi, bese injini ishayela umshini ukuze uqedele umsebenzi wokuvula. Ngalesi sikhathi, ukusebenza kokuvala noma ukusebenza phansi kungenziwa.

● Imisebenzi yokuvala nokumisa phansi:

Faka isibambo sokusebenza engxenyeni engezansi yomshini bese uyizungezisa ngokwewashi cishe ngamadigri angu-90. I-switch switch ivala isifunda somhlaba ngaphansi kwesenzo samandla entwasahlobo we-mechanical. Ngalesi sikhathi, isifunda esikhulu asikwazi ukuvalwa. Isibambo sokusebenza sijikeleza ngokuphambene newashi cishe ngamadigri angu-90, ukushintshwa komthwalo kuvulwa ngaphansi kwesenzo samandla entwasahlobo we-mechanical, futhi isifunda sokumisa singavulwa. Ngalesi sikhathi, ukusebenza kokuvala noma ukusebenza phansi kungenziwa.

Imingcele Eyinhloko Yezobuchwepheshe

CHA.

Into

Iyunithi

Inani

1

Isilinganiso sokuvama

Hz

50

2

Ikalwe okwamanje

A

630

3

Ilinganiselwe isikhathi esifushane ukumelana namanje

kA

20/25

4

Isilinganiso esiphakeme sokumelana nokumelana namanje

kA

63

5

Ilinganiselwe ubude besifunda esifushane

S

2

6

Ilinganiselwe isekethe emfushane yokwenza yamanje

kA

63

7

Inombolo yokusebenza kwethiyori

izikhathi

5000

Izinyathelo Zokusebenzisa Izimo Zemvelo

● Ukuphakama ≤ 2000m, kanye ne-seismic fissure ≤ 8 degrees.

● Izinga lokushisa lomoya we-ambient ngu-40℃~+40℃. Izinga lokushisa elihlobene isilinganiso sansuku zonke ≤90%, isilinganiso sanyanga zonke ≤90%.

● Izizinda zokufaka ezinokudlidliza okunodlame okuvamile, umhwamuko wamanzi, igesi, amadiphozithi amakhemikhali abolayo, uthuli nokungcola, nemililo ethinta kakhulu ukusebenza komshini, noma ezinezingozi zokuqhuma azifaneleki ukusetshenziswa.

I-htr (1)

I-C-GIS ye-C-GIS (enesinqamuli ngaphandle kokufaka umhlaba)

I-htr (4)

I-C-GIS ye-C-GIS (enesinqamuli ngaphandle kokufaka umhlaba)

I-htr (3)

I-switch break break ye-C-GIS (enezikhala zokusebenza ezi-2)

I-htr (2)

I-switch break break ye-C-GIS (enezikhala zokusebenza ezi-3)

Izici Zomkhiqizo

● Nikeza ngoxhumano oluhlukanisekayo oluvikelwe ngokugcwele futhi oluvalwe ngokugcwele uma lufaniswa nesihlahla esifanelekile noma ipulaki;

● Ingasebenza ngaphansi kwamanzi nezinye izimo ezinzima isikhathi eside;

● Indawo yokuhlola amandla eyakhelwe ngaphakathi isetshenziselwa ukunquma isimo esibukhoma solayini futhi kufanele isetshenziswe ngokuhambisana nesibonisi esishajiwe;

● Asikho isidingo sebanga elincane lokuphepha phakathi kwezigaba;

● Ukufakwa kungaba mpo, ovundlile nanoma iyiphi i-engeli.

imakethe

Isixhumi sangaphambili sesitayela saseYurophu

svv

Isixhumi sangemuva sesitayela saseYurophu

Izici Zomkhiqizo

● Nikeza ngoxhumano oluhlukanisekayo oluvikelwe ngokugcwele futhi oluvalwe ngokugcwele uma lufaniswa nesihlahla esifanelekile noma ipulaki;

● Ingasebenza ngaphansi kwamanzi nezinye izimo ezinzima isikhathi eside;

● Indawo yokuhlola amandla eyakhelwe ngaphakathi isetshenziselwa ukunquma isimo esibukhoma solayini futhi kufanele isetshenziswe ngokuhambisana nesibonisi esishajiwe;

● Asikho isidingo sebanga elincane lokuphepha phakathi kwezigaba;

● Ukufakwa kungaba mpo, ovundlile nanoma iyiphi i-engeli.

Izici Zomkhiqizo

● Isibambisi esingemuva sesitayela saseYurophu singanikeza ukuvikeleka okuthembekile kwe-over-voltage yesistimu kagesi. Uhlobo oluvikelekile olulandelwa ungqimba lwangaphandle lwe-semi-conductive yesibopheli luqinisekisa ukuphepha komuntu siqu kwabasebenzi bokufaka nokunakekela kanye nokusebenza okuphephile kwezinto zokusebenza. I-anti-ultraviolet, i-anti-aging, izici zokungangeni kwamanzi kanye nomswakama-umswakama ziqinisekisa ukuphepha nokuthembeka komkhiqizo ezindaweni ezinonya.

● Isibopheli sangemuva sesitayela saseYurophu sisebenzisana nesixhumi sangaphambili sesitayela saseYurophu ukuze kuqinisekiswe ukusebenza okuphephile kwegridi yamandla.

svv

Isibambi sangemuva sesitayela saseYurophu

sd

π-uhlobo lwesixhumi sangaphambili

Izici Zomkhiqizo

● Isixhumi sangaphambili esithintekayo sohlobo lwe-π sisetshenziswa ohlelweni lwenethiwekhi oluyinhloko lweyunithi eyinhloko yeringi, ibhokisi legatsha lekhebula noma uhlelo lwenethiwekhi eyindandatho yesiguquli sebhokisi, njengokuxhunywa kwezintambo ezingenayo neziphumayo. Ingaxhunywa kubha yebhasi engu-630A, futhi ingaxhunywa kusixhumi esingemuva esithintekayo soxhumano lwenhlanganisela eminingi ukwakha i-multi-circuit.

● Isixhumi sangaphambili esithintekayo sohlobo lwe-π sinesilinganiso samanje esingu-630A, silungele izintambo zikagesi ezinesigaba esiphambene esingu-25-300mm.2.

Izici Zomkhiqizo

● Ingahlinzeka ngoxhumano oluhlukanisekayo oluvaleleke ngokuphelele futhi oluvalwe ngokugcwele uma lufaniswa nesihlahla esifanelekile;

● Isigxobo esisodwa, i-plug-in design;

● Ibha yebhasi yenziwe ngezinsimbi zethusi, ezinongqimba lwe-silicone lwerabha engaphezulu;

● Uxhumo lwebha yebhasi lisebenzisa izixhumi zetheminali yerabha ye-silicone evalekile nezixhumi eziphambanayo;

● Ibhasi elivikelekile alinayo imfuneko yebanga elincane phakathi kwezigaba, futhi alithintwa ukungcola nokushiywa;

● Ibhasi elingavikelekile kufanele lifakwe isembozo sokuzivikela.

svv

Insulating ibhasi

svv

Ibhasi le-switchgear elizinikele

Izici Zomkhiqizo

● Uma ifaniswe nohlobo lwe-C-bushing, ingahlinzeka ngoxhumano oluhlukanisekayo oluvalwe ngokuphelele futhi oluvalwe ngokugcwele;

● Isigxobo esisodwa, i-plug-in design;

● Ibha yebhasi yakhiwe ngezinduku zethusi eziyindilinga (amashubhu) anesendlalelo se-silicone yerabha ngaphezulu;

● Ibhasi elivikelwe alinayo imfuneko yebanga lesigaba nesigaba, futhi alithintwa ukungcola nokushiywa.


  • Okwedlule:
  • Olandelayo: