I-ZW32-24 Series Outdoor High Voltage Vacuum Circuit Breaker (Evala kabusha)

Incazelo emfushane:


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

I-ZW32-24 yangaphandle ye-HV vacuum breaker iyisisetshenziswa se-AC 50Hz 24kV esinezigaba ezi-3

♦ Indlela yokufaka: i-pole mounted;

♦ Indlela yokusebenza: indlela yokusebenza yasentwasahlobo kanye nendlela yokusebenza kazibuthe unomphela;

♦ Uhlobo lwesigxobo: isigxobo esihlanganisiwe;

♦ Isicelo: isiteshi sangaphandle esingu-24kV, isizinda sikagesi.

♦ Uhlobo lokusebenza, imanuwali, ugesi, isilawuli kude.

Amazinga Omkhiqizo

♦ I-IEC62271-100 I-Voltge High Voltage Switchgear kanye ne-Controlgear Ingxenye 100: I-AC Circuit-breakers

♦ I-GB1984 High Voltage AC Circuit-breakers

♦ I-GB/T11022 Izicaciso Ezivamile ze-High-voltage Switchgear kanye ne-Controlgear

Amazinga

♦ I-JB/T 3855 High Voltage AC Vacuum Circuit-breakers

♦ Ukucaciswa kwe-DL/T402 kwama-High-voltage AC Circuit-breakers

Izimo Zemvelo

♦ Izinga lokushisa lendawo: -35°C~+40°C;

♦ Ukuphakama:

♦ Isivinini somoya

♦ Amandla okuzamazama komhlaba:

♦ Izinga elingcolile: IV;

♦ Izindawo zokufaka: Akukho mlilo, ingozi yokuqhuma noma ukungcola okukhulu.

Imingcele Eyinhloko Yezobuchwepheshe

Cha

Into

Iyunithi

Inani

1 I-voltage elinganiselwe

kV

amashumi amabili nane

2 Ikalwe okwamanje

A

630/1250

3 Isilinganiso sokuvama

Hz

50

4 Ikalwe ku-thermal current

kA

20/25

5 Ilinganiselwe ngokuphulwa kwesekethe emfushane

kA

20/25

6 Ikalwe ngokushintshashintsha kwamandla (ukuphakama)

kA

50/63

7 Isilinganiso sokuvala isiyingi esifushane (ukuphakama)

kA

50/63

8 Isikhathi sokuzinza kwe-thermal

s

4

9 Kukalwe ukulandelana kokusebenza

Izikhathi

O-0.3S-CO-1 80S-CO

10

Iminithi elingu-1 imvamisa yamandla imelana ne-voltage (isigaba esiphakathi, umhlaba/ukuphuka)

kV

65

Umfutho wombani umelana ne-voltage (isiqongo) (isigaba esiphakathi, umhlaba/ukuphuka)

125

Isekhethi yesibili 1min imvamisa yamandla imelana ne-voltage

2

 

Cha

Into

Iyunithi

Inani

11

Impilo yemishini Izikhathi

10000

12

Ilinganiselwe izikhathi zokuphuka kwesiyingi esifushane Izikhathi

30

13

Ilinganiswe izikhathi zokuphulwa kwesekethe Izikhathi

10000

14

Ibanga lokuxhumana

mm

12±1

15

Ukuhamba ngaphezulu

mm

3±1

16

Ibanga eliphakathi kwezigaba

mm

380±1.5

17

Izigaba ezintathu zokuvala nokuvula i-asynchronism

ms

≤2

18

Ubude besikhathi sokuvala othintana naye

ms

≤2

19

Isikhathi sokuvala

ms

25-80

20

Isikhathi sokuvula

ms

23-50

amashumi amabili nanye Isivinini sokuvula esimaphakathi

m/s

1.1-1.7

amashumi amabili nambili Isivinini sokuvala esimaphakathi

m/s

0.5-0.9

amashumi amabili nantathu

Ukumelana okuyinhloko kwesekethe ye-conductive

≤80

Umdwebo Wesakhiwo Esijwayelekile Nosayizi Wokufaka (iyunithi: mm)

svv

1. Itheminali yolayini ophumayo ophezulu 2. Isiphazamisi 3. Ishubhu le-insulating 4. Itheminali yolayini ophumayo ophansi

5. Isiqeshana se-conductive 6. Uxhumano oluguquguqukayo 7. I-insulating lever 8. Thintana ne-spring pressure

9. Ukuvulwa kwentwasahlobo 10. Shayela 11. Umshini ophumayo shaft 12. Indlela yokusebenza

13. Ibhokisi le-Mechanism 14. Ibhodi lokuxhumanisa i-transformer yamanje

njll

1. Isibambo esisebenzayo 2. Nqamula shaft eyinhloko 3. Isibambo se-circuit breaker sokuvula/ sokuvala isibambo

4. Isibambo sokugcina amandla 5. Inkomba yokuvula/yokuvala 6. Ipulaki yezintambo 7. I-transformer yamanje

8. Isivikelo 9. Uhlaka oluvamisile 10. Ilever evikelayo 11. Itheminali yolayini ongenayo

12. Nqamula i-blade 13. Itheminali yolayini ophumayo 14. Isinqamuli sesekhethi

 

Izindlela zokufaka (isigxobo esisodwa/isigxobo esikabili)

svv

 